Product >> Termination>> 3M Cold Shrink QT-III Termination - Single Conductor 冷縮預撐電纜 終端接頭QT-III 電纜處理頭 - 單蕊電纜
QT-III Silicone Rubber - Single Conductor
3M Cold Shrink QT-III terminations offer easy
installation and reliable performance when terminating indoor and
3M高壓終端處理頭第二代(QT2 淺灰色)內建電應力套管,但是終端處理頭之防水處理須要纏繞防水
膠帶,於電纜外半導體剝除處須纏繞 #13半導電膠帶及塗抹矽脂膏以防止產生部分放電,未提供電纜油污清潔劑.
預撐含膠式 電纜末端處理頭 (QT III Silicone Rubber) 您可能會需要: |
Cable Types for Terminating
Tape Shielded Cable
Wire Shielded Cable
UniShield Cable
Wire Over Tape Shielded Cable
LC Shielded Cable |
|
Concentric Neutral (CN) Cable
Jacketed
Concentric Neutral (JCN) Cable
Paper Insulated
Lead Covered (PILC) Cable Nonshielded (Dry) Cable
Nonshielded (Wet or Dry) Cable |
3M Cold Shrink QT-III Indoor Tubular Termination 終端處理頭QT-III 屋內型
產品型號 |
耐衝擊電壓 |
電纜絕緣外徑 O.D. Range |
導體尺寸線徑 AWG AND kcmil (mm2) |
||||
5 kV |
8 kV |
15 kV |
25/ 28 kV |
35 kV |
|||
7620-T-95 |
95 kV |
0.32 – 0.59 (8,1 – 15,0) |
8 – 4 |
8 – 6 |
— |
— |
— |
7621-T-95 |
95 kV |
0.44 – 0.89 (11,2 – 22,6) |
2 – 3/0 |
4 – 2/0 |
— |
— |
— |
7622-T-95 |
95 kV |
0.64 – 1.08 (16,3 – 27,4) |
4/0 – 400 |
3/0 – 300 |
— |
— |
— |
7624-T-95 |
95 kV |
0.83 – 1.53 (21,1 – 38,9) |
500 – 750 |
350 – 700 |
— |
— |
— |
7625-T-95 |
95 kV |
1.05 – 1.80 (26,7 – 45,7) |
700 – 1500 |
600 – 1250 |
— |
— |
— |
7622-T-110 |
110 kV |
0.64 – 1.08 (16,3 – 27,4) |
4/0 – 400 |
3/0 – 300 |
2 – 2/0 (35 – 70) |
— |
— |
7623-T-110 |
110 kV |
0.72 – 1.29 (18,3 – 32,8) |
300 – 500 |
250 – 500 |
2/0 – 300 (70 – 150) |
— |
— |
7624-T-110 |
110 kV |
0.83 – 1.53 (21,1 – 38,9) |
500 – 750 |
350 – 700 |
4/0 – 500 (120 – 240) |
— |
— |
7625-T-110 |
110 kV |
1.05 – 1.80 (26,7 – 45,7) |
700 – 1500 |
600 – 1250 |
500 – 1000 (240 – 500) |
— |
— |
7626-T-110 |
110 kV |
1.53 – 2.32 (38,9 – 58,9) |
1750 – 2000 |
1500 – 2000 |
1250 – 2000 (625 – 1000) |
— |
— |
7693-T-150 |
150 kV |
0.72 – 1.29 (18,3 – 32,8) |
300 – 500 |
250 – 500 |
2/0 – 300 (70 – 150) |
2 – 4/0 (35 – 120) |
2 – 2/0 (35 – 70) |
7695-T-150 |
150 kV |
1.05 – 1.80 (26,7 – 45,7) |
700 – 1500 |
600 – 1250 |
500 – 1000 (240 – 500) |
250 – 800 (150 – 400) |
3/0 – 600 (95 – 325) |
7696-T-150 |
150 kV |
1.53 – 2.32 (38,9 – 58,9) |
1750 – 2000 |
1500 – 2000 |
1250 – 2000 (625 – 1000) |
900 – 1750 (500 – 800) |
700 – 1500 (400 – 725) |
|
|
Cable Insulation O.D. 絕緣層外徑 |
導體線徑 Conductor Size Range AWG and kcmil (mm2) |
UPC |
Kit Number |
BIL |
Inch (mm) |
5 kV |
8.7 kV |
15 kV |
25/28 kV |
★35 kV |
054007- |
Shielded Cable Kits(Each kit makes three terminations) 適用銅帶/線遮蔽電纜
7620-T-95 |
95 kV |
0.32-0.59 (8,2-15,0) |
8-4(10~25) |
8-6(10~26) |
— |
— |
— |
41758 |
7621-T-95 |
95 kV |
0.44-0.89 (11,2-22,7) |
2-3/0(35~95) |
4-2/0(27~70) |
— |
— |
— |
41759 |
7622-T-110 |
110 kV |
0.64-1,08 (16,3-27,4) |
4/0-400 (120~200) |
3/0-300 (95~150) |
2-4/0 (35-120) |
— |
— |
41760 |
7624-T-110 |
110 kV |
0.83-1.53 (21,1-38,9) |
500-750 (250~380) |
350-700(170~350) |
4/0-500 (120-240) |
— |
— |
41761 |
7625-T-110 |
110 kV |
1.05-1.80 (26,7-45,7) |
700-1500 (350~725) |
600-1250 (300~625) |
500-1000 (240-500) |
— |
— |
41762 |
7626-T-110 |
110 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 (800~1000) |
1500-2000 (750~1000) |
1250-2000 (500-1000) |
— |
— |
41763 |
7693-T-150 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 (150~240) |
250-500 (150~240) |
2/0-300 (70-150) |
2-4/0 (35-120) 25KV 38mm2 |
2-2/0 (35-70) |
41778 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 (350~725) |
600-1250 (300~625) |
500-1000 (240-500) |
250-800 (150-400) 25kv 125 /250 m2 |
3/0-600 (95-325) |
41779 |
|
7696-T-150 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 (800~1000) |
1500-2000 (750~1000) |
1250-2000 (500-1000) |
900-1750 (500-800) |
700-1500 (400-725) |
41780 |
Concentric and Jacketed Concentric Cable Kits (Each kit makes one termination)
7642-T-110 |
110 kV |
0.64-1.08 (16,3-27,4) |
4/0-400 |
3/0-300 |
2-4/0 (35-120) |
— |
— |
41764 |
7644-T-110 |
110 kV |
0.83-1.53 (21,1-38,9) |
500-750 |
350-700 |
4/0-500 (120-240) |
— |
— |
41766 |
7645-T-110 |
110 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
— |
— |
41768 |
7646-T-110 |
110 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (500-1000) |
— |
— |
41770 |
7653-T-150 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250-500 |
2/0-300 (70-150) |
2-4/0 (35-120) |
2-2/0 (35-70) |
41772 |
7655-T-150 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
250-800 (150-400) |
3/0-600 (95-325) |
41774 |
7656-T-150 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (500-1000) |
900-1750 (500-800) |
700-1500 (400-725) |
41776 |
High Fault Current Cable Kits(Each kit makes one termination)
7642-T-HSG-110 |
110 kV |
0.64-1.08 (16,3-27,4) |
4/0-400 |
3/0-300 |
2-4/0 (35-120) |
— |
— |
41765 |
7644-T-HSG-110 |
110 kV |
0.83-1.53 (21,1-38,9) |
500-750 |
350-700 |
4/0-500 (120-240) |
— |
— |
41767 |
7645-T-HSG-110 |
110 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
— |
— |
41769 |
7646-T-HSG-110 |
110 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (500-1000) |
— |
— |
41771 |
7653-T-HSG-150 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250-500 |
2/0-300 (70-150) |
2-4/0 (35-120) |
2-2/0 (35-120) |
41773 |
7655-T-HSG-150 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
250-800 (150-400) |
3/0-600 (95-325) |
41775 |
7656-T-HSG-150 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (500-1000) |
900-1750 (500-800) |
700-1500 (400-725) |
41777 |
★
150kV impulse level meets the impulse requirements for 35.0kV class equipment where indoor terminations are used.3M Cold Shrink QT-III Outdoor Skirted Termination 終端處理頭QT-III 屋外型
762X-S-2 | 769X-S-4 |
768X-S-8 |
|
|
Cable Insulation O.D. |
Conductor Size Range AWG and kcmil (mm2) |
UPC |
Kit Number |
BIL |
Inch (mm) |
5 kV |
8.7 kV |
15 kV |
25/28 kV |
★35 kV |
054007- |
Shielded Cable Kits(Each kit makes three terminations) 適用銅帶/線遮蔽電纜
7620-S-2 |
95 kV |
0.32-0.59 (8,2-15,0) |
8-4 (10-25) |
8-6 (10-16) |
— |
— |
— |
42168 |
||
7621-S-2 |
95 kV |
0.44-0.89 (11,2-22,7) |
2-3/0 (35-95) |
4-2/0 (25-70) |
— |
— |
— |
42169 |
||
7622-S-2 |
110 kV |
0.64-1,08 (16,3-27,4) |
4/0-400 (120-200) |
3/0-300 (95-150) |
2-4/0 (35-120) |
— |
— |
42170 |
||
7692-S-4 |
150 kV |
0.64-1,08 (16,3-27,4) |
4/0-400 (120-200) |
3/0-300 (95-150) |
2-4/0 (35-120) |
2-1/0 (35-50) |
— |
42211 |
||
7693-S-4 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 (150-240) |
250-500 (130-240) |
2/0-300 (70-150) |
2-4/0 (35-120) |
— |
42212 |
||
7694-S-4 |
150 kV |
0.83-1.53 (21,1-38,9) |
500-750 (240-380) |
350-700 (170-350) |
4/0-500 (120-240) |
2/0-250 (70-150) |
— |
42213 |
||
7695-S-4 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 (350-725) |
600-1250 (300-625) |
500-1000 (240-500) |
250-800 (125-400) |
— |
42214 |
||
7696-S-4 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 (800-1000) |
1500-2000 (725-1000) |
1250-2000 (625-1000) |
900-1750 (500-800) |
— |
42215 |
||
7683-S-8 |
200 kV |
0.72-1.29 (18,3-32,8) |
300-500 (150-240) |
250-500 (125-240) |
2/0-300 (70-150) |
2-4/0 (35-120) |
2-2/0 (35-70) |
42465 |
||
7684-S-8 |
200 kV |
0.83-1.53 (21,1-38,9) |
500-750 (240-380) |
350-700 (170-350) |
4/0-500 (120-240) |
2/0-250 (70-150) |
2-4/0 (35-120) |
42466 |
||
7685-S-8 |
200 kV |
1.05-1.80 (26,7-45,7) |
700-1500 (350-725) |
600-1250 (300-625) |
500-1000 (240-500) |
250-800 (125-400) |
3/0-600 (95-325) |
42467 |
||
7686-S-8 |
200 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 (800-1000) |
1500-2000 (725-1000) |
1250-2000 (625-1000) |
900-1750 (500-800) |
700-1500 (400-725) |
42468 |
Concentric and Jacketed Concentric Cable Kits(Each kit makes one termination)
7642-S-2 |
110 kV |
0.64-1.08 (16,3-27,4) |
4/0-400 |
3/0–300 |
2–4/0 (35–120) |
— |
— |
42011 |
7652-S-4 |
150 kV |
0.64-1.08 (16,3-27,4) |
4/0-400 |
3/0–300 |
2–4/0 (35–120) |
2-1/0 (35-120) |
— |
42178 |
7653-S-4 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250–500 |
2/0–300 (70–150) |
2-4/0 (35-120) |
— |
42192 |
7654-S-4 |
150 kV |
0.83-1.53 (21,1-38,9) |
500-750 |
350–700 |
4/0–500 (120–240) |
2/0-250 (70-150) |
— |
42203 |
7655-S-4 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600–1250 |
500–1000 (240–500) |
250-800 (150-400) |
— |
42208 |
7656-S-4 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500–2000 |
1250–2000 (625–1000) |
900-1750 (500-800) |
— |
42210 |
7663-S-8 |
200 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250–500 |
2/0–300 (70–150) |
2-4/0 (35-120) |
2-2/0 (35-70) |
42433 |
7664-S-8 |
200 kV |
0.83-1.53 (21,1-38,9) |
500-750 |
350–700 |
4/0–500 (120–240) |
2/0-250 (70-150) |
2-4/0 (35-120) |
42447 |
7665-S-8 |
200 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600–1250 |
500–1000 (240–500) |
250-800 (150-400) |
3/0-600 (95-325) |
42461 |
7666-S-8 |
200 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500–2000 |
1250–2000 (625–1000) |
900-1750 (500-800) |
700-1500 (400-725) |
42463 |
Kit No. |
BIL |
Cable Insulation O.D. Range in. (mm) |
5 kV |
8.7 kV |
Conductor Size Range AWG and kcmil (mm2) 15 kV |
25/28 kV |
35 kV |
UPC (054007-) |
High Fault Current Cable Kits(Each kit makes one termination)
7652-S-HSG-4 |
150 kV |
0.64-1.08 (16,3-27,4) |
4/0-400 |
3/0-300 |
2-4/0 (35-120) |
2-1/0 (35-50) |
— |
42171 |
7653-S-HSG-4 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250-500 |
2/0-300 (70-150) |
2-4/0 (35-120) |
— |
42185 |
7654-S-HSG-4 |
150 kV |
0.83-1.53 (21,1-38,9) |
500-750 |
350-700 |
4/0-500 (120-240) |
2/0-250 (70-150) |
— |
42199 |
7655-S-HSG-4 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
250-800 (150-400) |
— |
42207 |
7656-S-HSG-4 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (625-1000) |
900-1750 (500-800) |
— |
42209 |
7663-S-HSG-8 |
200 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250-500 |
2/0-300 (70-150) |
2-4/0 (35-120) |
2-2/0 (35-70) |
42440 |
7664-S-HSG-8 |
200 kV |
0.83-1.53 (21,1-38,9) |
500-750 |
350-700 |
4/0-500 (120-240) |
2/0-250 (70-150) |
2-4/0 (35-120) |
42454 |
7665-S-HSG-8 |
200 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
250-800 (125-400) |
3/0-600 (95-325) |
42462 |
7666-S-HSG-8 |
200 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (625-1000) |
900-1750 (500-800) |
700-1500 (400-725) |
42464 |
Inverted Kits for Shielded Cable(Each kit makes three terminations)
Inverted
7622-S-INV-2 |
110 kV |
0.64-1.08 (16,3-27,4) |
4/0-400 |
3/0-300 |
2-4/0 (35-120) |
— |
— |
43016 |
|
7693-S-INV-4 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250-500 |
2/0-300 (70-150) |
2-4/0 (35-120) |
2-2/0 (35-70)* |
43017 |
|
7695-S-INV-4 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
250-800 (150-400) |
3/0-600 (95-325)* |
43018 |
|
7696-S-INV-4 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (500-1000) |
900-1750 (500-800) |
700-1500 (400-725)* |
43019 |
Inverted Kits for Concentric and Jacketed Concentric Cable(Each kit makes one termination)
7642-S-INV-2 |
110 kV |
0.64-1.08 (16,3-27,4) |
4/0-400 |
3/0-300 |
2-4/0 (35-120) |
— |
— |
04622 |
7653-S-INV-4 |
150 kV |
0.72-1.29 (18,3-32,8) |
300-500 |
250-500 |
2/0-300 (70-150) |
2-4/0 (35-120) |
2-2/0 (35-70)* |
04625 |
7655-S-INV-4 |
150 kV |
1.05-1.80 (26,7-45,7) |
700-1500 |
600-1250 |
500-1000 (240-500) |
250-800 (150-400) |
3/0-600 (95-325)* |
04623 |
7656-S-INV-4 |
150 kV |
1.53-2.32 (38,9-58,9) |
1750-2000 |
1500-2000 |
1250-2000 (625-1000) |
900-1750 (500-800) |
700-1500 (400-725)* |
04624 |
*35kV weather protected applications only
3M Cold Shrink QT-III Silicon Rubber Termination with Top Insulator
Kit No. |
BIL |
Cable Insulation O.D. Range in. (mm) |
Connector & Drop Wire O.D. Range |
5 kV |
8.7 kV |
Conductor Size Range AWG and kcmil (mm2) 15 kV |
25/28kV |
UPC (054007-) |
Concentric and Jacketed Concentric Cable Kits with Top Insulator (Each kit makes one termination)
7642-S-4-TI |
|
0.64-1.08 (16,3-27,4) |
0.97-1.48 (24,6-37,6) |
4/0-400 |
3/0-300 |
2-4/0 (35-120) |
— |
— |
7652-S-4-TI |
150 kV |
0.64-1.08 (16,3-27,4) |
0.51-0.82 (12,9-20,8) |
4/0-400 |
3/0-300 |
2-4/0 (35-120) |
2-1/0 (35-50) |
43409 |
7653-S-4-TI |
150 kV |
0.72-1.29 (18,3-32,8) |
0.62-1.0 (15,7-25,4) |
300-500 |
250-500 |
2/0-300 (70-150) |
2-4/0 (35-120) |
43410 |
7654-S-4-TI |
150 kV |
0.83-1.53 (21,1-38,9) |
0.66-1.18 (16,7-30,0) |
500-750 |
350-700 |
4/0-500 (120-240) |
2/0-250 (70-150) |
43411 |
7655-S-4-TI |
150 kV |
1.05-1.80 (26,7-45,7) |
0.69-1.30 (17,5-33,0) |
700-1500 |
600-1250 |
500-1000 (240-500) |
250-800 (150-400) |
43412 |
7656-S-4-TI |
150 kV |
1.53-2.32 (38,9-58,9) |
1.05-1.94 (26,6-49,3) |
1750-2000 |
1500-2000 |
1250-2000 (625-1000) |
900-1750 (500-800) |
43413 |
高壓電與處理頭,各式產品比較表:
冷縮式 | 熱縮式 | 預鑄式 | |
電應力控制方法 | 折射擴散法 | 形狀擴散法 | 折射擴散法 |
材質(耐候性) | 矽橡膠 | EVA | EPDM |
適用範圍 | 一套管可適用多種線徑 庫存管理簡易 | 一套管可適用多種線徑 庫存管理簡易 | 一個電力錐,僅適用一種線徑庫存管理不易 |
施工時間(不含電讚準備工作) | 約6分鐘即可完成 | 約15分鐘可完成 | 約15分鐘可完成 |
施工品質 | 穩定可靠 | 視工作人員熟練程度而定 | 視工作人員熟練程度而定 |
完成長度 | 約350mm(25kV,屋內) | 約580mm(25kV,屋內) | 約530mm(25kV,屋內) |
防水性 | 佳 | 尚可 | 尚可 |
電纜彎折配合度 | 可隨電纜彎折,不影響 其防水性(適形性佳) | 不好 | 不好 |
技術支援及售後服務 | 技術中心在台提供 技術支援,售後服務 | 原廠代理商在台 提供售後服務 | 由貿易商引進 |
交貨 | 國內生產,交貨迅速 | 國內並沒有工廠生產 | 國內並沒有工廠生產 |
您可能會需要:
Tubular Cable Lug 加長型 (高壓) 單孔銅管端子/加長型 (高壓) 雙孔銅管端子
For other QT-II termination 其他 3M QT-II電纜處理頭
3M Cable Cleaning System 電纜清潔劑
中央商業有限公司 Power Hub Inc.